Search anything and hit enter
  • Teams
  • Members
  • Projects
  • Events
  • Calls
  • Jobs
  • publications
  • Software
  • Tools
  • Network
  • Equipment

A little guide for advanced search:

  • Tip 1. You can use quotes "" to search for an exact expression.
    Example: "cell division"
  • Tip 2. You can use + symbol to restrict results containing all words.
    Example: +cell +stem
  • Tip 3. You can use + and - symbols to force inclusion or exclusion of specific words.
    Example: +cell -stem
e.g. searching for members in projects tagged cancer
Search for
Count
IN
OUT
Content 1
  • member
  • team
  • department
  • center
  • program_project
  • nrc
  • whocc
  • project
  • software
  • tool
  • patent
  • Administrative Staff
  • Assistant Professor
  • Associate Professor
  • Clinical Research Assistant
  • Clinical Research Nurse
  • Clinician Researcher
  • Department Manager
  • Dual-education Student
  • Full Professor
  • Honorary Professor
  • Lab assistant
  • Master Student
  • Non-permanent Researcher
  • Nursing Staff
  • Permanent Researcher
  • Pharmacist
  • PhD Student
  • Physician
  • Post-doc
  • Prize
  • Project Manager
  • Research Associate
  • Research Engineer
  • Retired scientist
  • Technician
  • Undergraduate Student
  • Veterinary
  • Visiting Scientist
  • Deputy Director of Center
  • Deputy Director of Department
  • Deputy Director of National Reference Center
  • Deputy Head of Facility
  • Director of Center
  • Director of Department
  • Director of Institute
  • Director of National Reference Center
  • Group Leader
  • Head of Facility
  • Head of Operations
  • Head of Structure
  • Honorary President of the Departement
  • Labex Coordinator
Content 2
  • member
  • team
  • department
  • center
  • program_project
  • nrc
  • whocc
  • project
  • software
  • tool
  • patent
  • Administrative Staff
  • Assistant Professor
  • Associate Professor
  • Clinical Research Assistant
  • Clinical Research Nurse
  • Clinician Researcher
  • Department Manager
  • Dual-education Student
  • Full Professor
  • Honorary Professor
  • Lab assistant
  • Master Student
  • Non-permanent Researcher
  • Nursing Staff
  • Permanent Researcher
  • Pharmacist
  • PhD Student
  • Physician
  • Post-doc
  • Prize
  • Project Manager
  • Research Associate
  • Research Engineer
  • Retired scientist
  • Technician
  • Undergraduate Student
  • Veterinary
  • Visiting Scientist
  • Deputy Director of Center
  • Deputy Director of Department
  • Deputy Director of National Reference Center
  • Deputy Head of Facility
  • Director of Center
  • Director of Department
  • Director of Institute
  • Director of National Reference Center
  • Group Leader
  • Head of Facility
  • Head of Operations
  • Head of Structure
  • Honorary President of the Departement
  • Labex Coordinator
Search

← Go to Research

Go back
Scroll to top
Share
© Research
Publication : International Journal of Mass Spectrometry

Ion source parameters and hydrogen scrambling in the ECD of selectively deuterated peptides

Scientific Fields
Diseases
Organisms
Applications
Technique

Published in International Journal of Mass Spectrometry - 15 Jun 2014

Magalie Duchateau, Thomas J.D. Jørgensen, Ophélie Robine, Edith Nicol, Christian Malosse, Julia Chamot-Rooke, Guillaume van der Rest

IJMS, 2014, 367, 21:27

Hydrogen/deuterium exchange monitored by mass spectrometry (HDX-MS) has become an important method to study protein dynamics in solution. Recently, electron-based fragmentation methods (ECD and ETD) have been utilized in HDX-MS/MS experiments as experimental tools to increase the spatial resolution (the ability to obtain deuterium levels of individual residues). An essential prerequisite for this approach is that the level of hydrogen scrambling is negligible. The occurrence of hydrogen scrambling depends critically on the extent of vibrational excitation in the mass spectrometer. In particular, the desolvation process in the electrospray ion source is likely to induce scrambling at standard operating conditions. Consequently, finding experimental conditions that minimize hydrogen scrambling to a negligible level is thus pivotal for the application of electron-based fragmentation in HDX-MS/MS experiments. In the present work, we investigate the occurrence of scrambling in the Apollo I electrospray ion source using ECD of selectively deuterium labeled peptides. The electrospray ion source settings leading to minimal scrambling were identified. Furthermore, an energy dependent loss of deuterium occurring in the ion source was also observed. This loss was critically dependent on the occurrence of scrambling.