Search anything and hit enter
  • Teams
  • Members
  • Projects
  • Events
  • Calls
  • Jobs
  • publications
  • Software
  • Tools
  • Network
  • Equipment

A little guide for advanced search:

  • Tip 1. You can use quotes "" to search for an exact expression.
    Example: "cell division"
  • Tip 2. You can use + symbol to restrict results containing all words.
    Example: +cell +stem
  • Tip 3. You can use + and - symbols to force inclusion or exclusion of specific words.
    Example: +cell -stem
e.g. searching for members in projects tagged cancer
Search for
Count
IN
OUT
Content 1
  • member
  • team
  • department
  • center
  • program_project
  • nrc
  • whocc
  • project
  • software
  • tool
  • patent
  • Administrative Staff
  • Assistant Professor
  • Associate Professor
  • Clinical Research Assistant
  • Clinical Research Nurse
  • Clinician Researcher
  • Department Manager
  • Dual-education Student
  • Full Professor
  • Honorary Professor
  • Lab assistant
  • Master Student
  • Non-permanent Researcher
  • Nursing Staff
  • Permanent Researcher
  • Pharmacist
  • PhD Student
  • Physician
  • Post-doc
  • Prize
  • Project Manager
  • Research Associate
  • Research Engineer
  • Retired scientist
  • Technician
  • Undergraduate Student
  • Veterinary
  • Visiting Scientist
  • Deputy Director of Center
  • Deputy Director of Department
  • Deputy Director of National Reference Center
  • Deputy Head of Facility
  • Director of Center
  • Director of Department
  • Director of Institute
  • Director of National Reference Center
  • Group Leader
  • Head of Facility
  • Head of Operations
  • Head of Structure
  • Honorary President of the Departement
  • Labex Coordinator
Content 2
  • member
  • team
  • department
  • center
  • program_project
  • nrc
  • whocc
  • project
  • software
  • tool
  • patent
  • Administrative Staff
  • Assistant Professor
  • Associate Professor
  • Clinical Research Assistant
  • Clinical Research Nurse
  • Clinician Researcher
  • Department Manager
  • Dual-education Student
  • Full Professor
  • Honorary Professor
  • Lab assistant
  • Master Student
  • Non-permanent Researcher
  • Nursing Staff
  • Permanent Researcher
  • Pharmacist
  • PhD Student
  • Physician
  • Post-doc
  • Prize
  • Project Manager
  • Research Associate
  • Research Engineer
  • Retired scientist
  • Technician
  • Undergraduate Student
  • Veterinary
  • Visiting Scientist
  • Deputy Director of Center
  • Deputy Director of Department
  • Deputy Director of National Reference Center
  • Deputy Head of Facility
  • Director of Center
  • Director of Department
  • Director of Institute
  • Director of National Reference Center
  • Group Leader
  • Head of Facility
  • Head of Operations
  • Head of Structure
  • Honorary President of the Departement
  • Labex Coordinator
Search

← Go to Research

Go back
Scroll to top
Share
© Research
Publication : Journal of immunological methods

Measurement of the dissociation rate constant of antigen/antibody complexes in solution by enzyme-linked immunosorbent assay

Scientific Fields
Diseases
Organisms
Applications
Technique

Published in Journal of immunological methods - 15 Apr 1994

Larvor MP, Djavadi-Ohaniance L, Nall B, Goldberg ME

Link to Pubmed [PMID] – 8157995

J. Immunol. Methods 1994 Apr;170(2):167-75

A reliable, convenient ELISA based method has been developed for measuring the dissociation rate constants of antigen/antibody complexes in solution. Its rationale is as follows: a solution containing the preformed antigen/antibody complex is diluted well below the equilibrium dissociation constant to initiate the dissociation and, at various times after the dilution, the amount of dissociated antibody contained in an aliquot is determined by a classical ELISA, using a brief incubation of the solution in antigen coated wells. To test the validity of this method, the dissociation rate constants for several antigen/antibody complexes were compared with those obtained by classical fluorescence based methods. The good agreement between both sets of data validates the ELISA procedure. The present method offers several advantages. It uses only minute amounts of sample which need not be purified; it requires no radioactive or fluorescent labelling of the antibody or antigen, and it can, in principle, be applied to any type of complex between macromolecules if an ELISA test can be set up to detect quantitatively one of the macromolecules.